The DMC 2000S - Personal Electronic Dosimeter - Gamma
The DMC 2000S features flat energy response to X-rays and gamma field from 50keV to 6Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass-by data exchange feature gives unequal operational flexibility. In-motion reading allows dose management by sub-zone as well as real-time location tracking of personnel.
FEATURES:
The DMC 2000S features display of dose, dose rate and programmable alarms
- The DMC 2000S is user friendly, lightweight and waterproof
- Can be used as a Stand-alone device or integrated into a dosimetry system
- Audible and visual alarms
- Large internal histogram memory
- Self-testing diagnostics (battery, detector and parameters)
- Hands-free communication, pass-by exchange
TECHNICAL SPECIFICATIONS:
Radiological Characteristics
- compliant to IEC 1283, ANSI 4220A
- PTB approved
- display units: mSv or mrem
- measurement range:
- dose:1μSv to 10Sv (0.1mrem to 10 rem)
- rate: 0.1 μSv/h to 10 Sv/h (0.01 mrem/h to 1000 rem/h)
- display: 0.01 mSv/h to 10 Sv/h or 0.001 mSv/h to 10 Sv/h (extended option)
- linearity: <± 10% up to 1 Sv/h (100 rem/h)
- <± 25% up to 10 Sv/h (1000 rem/h)
- X and Gamma energy range: 50 keV to 6 MeV
- accuracy: <± 5% (137Cs, 0.2 mSv/h)
Electrical Characteristics
- standard calculator battery LiMnO2 CR2450, one year battery life (typical)
Mechanical Characteristics
- dimensions: 84 x 48 x 17.5mm (3.3 in x 1.9 in x 0.7 in)
- weight with battery: < 70g (2.2 oz)
- worn by a replacable clip
Environmental Characteristics
- temperature range: -10°C to 50°C (14°F to 122°F)
- humidity: < 90% at 42° (108°F)
- storage: -30°C to 71°C (-22°F to 160°F)
- shock, vibration and drop resistant waterproof
- EMC: complies and exceeds standards by a large margin
0 komentar: